Visible on the surface of the paint and mostly appears around filler and primer spot repairs that are extended in the surrounding area of the spot.
Incorrect sanding process of fillers or 2K primers.
Usually due to the use of too coarse sanding paper.
Filler spot repair insufficiently covered with 2K filler.
Filler or primer sanded prior to proper drying.
Incorrect sanding techniques, tools, sanding block or sanding disk machine.
Use correct sanding coarse papers.
Remove scratches from every sanding step prior to the next application.
In case of filler spot repair, cover properly all surrounding areas of the repair with 2K primer.
-
Can products be transported in temperatures bellow 0°C?
Most of the products, made by HB BODY SA, are solvent-based, so transportation below 0°C should not be a problem. Products that have problems at low temperatures are products based in water, for the sole reason that water freezes at 0°C
-
Which is the lowest recommended temperature for product application?
The ideal temperature for product application is room temperature and that is 21°C. Product application becomes difficult at temperatures with large deviations from the ideal since the application viscosity increases or decreases (temperature dependent). The lowest recommended product application is about 5-8°C for primers, paints, clear coats and underbody applications. The commonest application temperature for putties is 5°C.
-
What is the shelf-life of a product?
The shelf life of our products is indicated on each Technical Data Sheet (TDS) and outlines the period during which optimal quality and effectiveness are ensured. Proper storage conditions (+5°C - +25°C) (41°F - 77°F), intact packaging, and sealing are essential for maintaining product performance.
Shelf life can vary between product categories and even among products within the same category due to variations in formulation, materials, and ingredients. To guarantee lasting quality, it's crucial to adhere to recommended storage conditions, including avoiding exposure to humidity levels above 80% and direct sunlight.